McPherson M40E Air Curtain Burner FAQ

Setup, operation and maintenance answers for the McPherson Systems M40E air curtain burner. See McPherson machines for sale and for rent.

Air curtain burner and excavator burning land-clearing debris

48 questions in 1 section. Section 1 is open; select any question to read its answer.

1
Section 1 · Questions 1–48

McPherson M40E Operation and Maintenance

48 questions
1

What is the model name and equipment type covered by this operator's manual?

M40E Waste Burner / Refractory Lined Pit Burner.

2

Who manufactures the M40E Waste Burner?

McPherson Systems, Inc., located in Tifton, Georgia.

3

What is the phone number and email address for McPherson Systems, Inc.?

Phone: (229) 386-2367; Email: mcsales@mcphersys.com.

4

What are the office hours for McPherson Systems, Inc. customer support?

8:00 A.M. to 5:00 P.M. EST, Monday through Friday.

5

What warning is given to operators prior to starting the M40E machine?

Caution: Read Owner's Manual before operation; do not start the machine unless you understand these instructions, as failure to read this manual could result in personal injury and/or equipment and property damage.

6

What should happen to the operator's manual if the M40E is sold?

This manual is a permanent part of the machine and should remain with the machine should you decide to sell it.

7

What is the operating principle of the M40E Refractory Lined Pit Burner?

It creates and maintains a uniform curtain of air across the top of a refractory lined pit in which burning is done, prohibiting smoke from leaving the pit and increasing burning efficiency by adding oxygen.

8

What are the typical operating temperatures inside the refractory lined pit during burning?

Operating temperatures in the pit run between 1800�F and 2200�F.

9

Why are tractor or forklift tire stops not needed for M40E operation?

Because the refractory lined pit is constructed above ground level.

10

What kind of waste materials is the machine designed to burn?

All non-treated wastes.

11

Under what weather conditions can the M40E machine be operated properly?

Only when the weather is clear; rain or low clouds are not suitable conditions for burning.

12

What should an operator do if wind gusts occur during burning operations?

Stop loading the pit and allow the machine to operate until the fire has burned down.

13

How full should the pit be loaded with waste before cold ignition?

Load the pit 1/2 full with waste.

14

How much accelerant is used for cold ignition, and where should it be poured?

Douse the waste with 1 pint of fuel oil or diesel fuel, putting the majority of the oil on the waste at the front center side of the pit.

15

What types of ignition fluids are strictly prohibited?

Do NOT use highly volatile solvents such as mineral spirits, gasoline, etc. for ignition.

16

What agency should be contacted regarding local restrictions on accelerants?

Call your local EPA office for clarification, as some states do not allow the use of accelerants.

17

When should the air supply fan be introduced during a cold start?

Allow sufficient time for the fire to take hold before introducing any air from the air supply.

18

At what fan speed should the fan initially be set as the fire grows in intensity?

Turn the fan on at approximately 1100 RPM until ignition is uniform across the pit (usually 10 to 15 minutes).

19

What restriction must be observed regarding material height when loading the pit?

Ensure that no material protrudes above the air curtain when loading the pit.

20

When is the air supply fan turned on fully during the loading sequence?

Turn on the air supply fan after the fire has ignited across the pit.

21

Under what condition can the accelerant and manual lighting steps be omitted during start-up?

Steps 2 & 3 can be omitted if the pit has enough coals remaining from burning the day before.

22

Why must the fan be started differently when relighting hot coals from the previous day?

It will be necessary to introduce air from the fan before burning can start.

23

How far in advance of the desired shutdown must pit loading stop?

Approximately 2 hours before shut down is desired, stop loading the pit with material.

24

Why must the air supply fan remain running during the shutdown process?

To ensure the air curtain remains active and allows the remaining material to burn down in the pit.

25

When should the air supply be turned off during shutdown?

Turn off the air supply when the fire inside the pit has completely burned out.

26

When is it safe to unload ashes from the pit?

Allow ashes to cool before unloading them from the pit.

27

Why is regular ash removal required?

Ash removal is required in order to maintain efficient and proper combustion.

28

What is the maximum permissible level of ash buildup in the pit?

Ashes should not be allowed to build up higher than 1/3 the pit depth, or to the point where they begin to impede combustion and blow out of the pit, whichever occurs first.

29

What preparation is required before removing ashes from the pit?

Ashes should be saturated with water for cooling and dust control before removal.

30

How deep should wet ashes be spread after removal to ensure complete cooling?

Spread them out approximately 6 to 12 inches deep to allow total cooling to take place before final disposal.

31

Which components on the M40E require daily greasing?

Main Fan Bearings (2 locations per fan), Underfire Blower (2 locations), and Midfire Blower (2 locations).

32

How many lubrication points are on the main fan bearings daily?

2 locations per fan.

33

How many lubrication points are on the underfire and midfire blowers daily?

2 points on the Underfire Blower and 2 points on the Midfire Blower.

34

Which components require weekly greasing on the M40E?

Idler arm bushing (1 per fan).

35

Which components require monthly greasing on the M40E?

Bottom doors (12 locations).

36

When should the door hinges be greased on the M40E?

Hinges should be greased before the doors open.

37

What is the warranty coverage period for the M40E pit burner?

One year, beginning with the date of sale of the pit burner by McPherson Systems, Inc.

38

What failures are covered under the McPherson Systems warranty?

Any failure of the Product which results, under normal use and service, from a defect in material or workmanship (Warrantable Failure).

39

What items are explicitly excluded from warranty coverage?

Belts and service items are not covered by the warranty.

40

What are McPherson Systems' responsibilities during a warrantable failure?

McPherson Systems will furnish all parts and labor needed to repair the damage to the product resulting from the Warrantable Failure.

41

What are the owner's responsibilities for maintaining the warranty?

The owner is responsible for the operation and maintenance of the burner as specified in the operator's manual.

42

What procedure must the owner follow before the warranty expires to claim repairs?

The owner must notify McPherson Systems, Inc. of any Warrantable Failure and have the failure repaired by an official warranty facility.

43

What hours and phone number are available to locate official warranty service centers?

Call 1-229-386-2367 from 9:00 A.M. to 5:00 P.M. EST, Monday through Friday.

44

Who pays for maintenance items replaced during warranty repairs?

The owner is responsible for the cost of maintenance items replaced during warranty repairs, unless such items are not reusable due to Warrantable Failure.

45

Who is responsible for communication and freight expenses during a warranty claim?

The owner is responsible for communication expenses and similar costs; all warrantable items are F.O.B. Tifton, Georgia.

46

Is McPherson Systems, Inc. liable for downtime expenses, cargo damage, or incidental damages?

No; the owner is responsible for non-product repairs, downtime expenses, cargo damage, and all business costs and losses. McPherson Systems is not responsible for incidental or consequential damages.

47

What action voids the warranty on the M40E?

The warranty is void and nonbinding if, at the time of failure, the product is determined to have been modified so as to alter its operating characteristics.

48

How are components not manufactured by McPherson Systems warranted?

Components not manufactured by McPherson Systems, Inc. are subject to the warranty imposed by the manufacturer of that component.